OR Foundation
  • About
    • Oral Reconstruction Foundation
      • Purpose and Mission
      • Foundation Board
      • Scientific Working Group
      • Education Working Group
      • History
      • Career
      • News
  • Granting
    • Requirements
    • Application
  • Publications
    • Grant Publications
    • Consensus Publications
  • Awards
    • Research Award
      • Awards 2018/2019
      • Award 2016/2017
      • Award 2014/2015
      • Award 2012/2013
      • Award 2010/2011
      • Award 2008/2009
    • Poster Competition
      • Competition 2018
      • Competition 2016
      • Competition 2014
      • Competition 2012
  • Education
    • International Symposia
    • Global Symposia
    • National Symposia
    • Curriculum
    • Education Courses
    • Webinars
  • Contact
Select Page

Accuracy of three dimensional printed templates for guided implant placement based on matching a surface scan with CBCT.


Kernen F, Benic GI, Payer M, Schär A, Müller-Gerbl M, Filippi A, Kühl S

Clin Implant dent Relat Res 2016;18(4):762-8 (Grant CF20904)

Abstract

Background:

Reference elements are necessary to transfer a virtual planning into reality for guided implant placement. New systems allow matching optical scans with three-dimensional radiographic images.

Purpose:

To test whether digitally designed three-dimensional printed templates (D-temp) fabricated by matching surface scans and cone beam computed tomography (CBCT) images differ from the templates fabricated in-lab (L-temp) by using a physical transfer device for the positioning of the guiding sleeves.

Material and methods:

L-temp were fabricated for eight human lower cadaver-jaws applying a digital planning software program (smop, Swissmeda AG, Zürich, Switzerland) using a Lego® (Lego Group, KIRKBI A/S, Billund, Denmark) brick as reference element and the respective transfer device (X1-table). Additionally, digital templates (D-temp) using the identical planning data sets and software were virtually designed and three-dimensional printed, after matching a surface scan with CBCT data. The accuracy of both templates for each planning was evaluated determining the estimated coronal, apical, and angular deviation if templates were used for implant placement.

Results:

Mean coronal deviations for L-temp were 0.31 mm (mesial/distal), 0.32 mm (lingual/buccal), and 0.16 mm and 0.23 mm for D-temp, respectively. The mean apical deviations for L-temp were 0.50 mm (mesial/distal), 0.50 mm (lingual/buccal). and 0.25 mm and 0.34 mm for the D-temp, respectively. Differences between both devices were statistically significant (p < .05).

Conclusion:

A higher accuracy of implant placement can be achieved by using three-dimensional printed templates produced by matching a surface scan and CBCT as compared with templates which use physical elements transferring the virtual planning into reality.

SOURCE

Latest Research Award Winners

Dr. Yifan Zhang
Quantitative Clinical Adjustment Analysis of Posterior Single Implant Crown in a Chairside Digital Workflow: A Randomized Controlled Trial. Clin Oral Impl Res. 2019;30:1059-1066

Read more

Dr. Hyun-Chang Lim
Tissue integration of zirconia and titanium implants with and without buccal dehiscence defects — A histologic and radiographic preclinical study. Clin Oral Impl Res. 2019;30:660-9

Read more

Dr. Lorenzo Tavelli
Acellular dermal matrix and coronally advanced flap or tunnel technique in the treatment of multiple adjacent gingival recessions. A 12-year follow-up from a randomized clinical trial. J Clin Periodontol. 2019;46:937-48

Read more

Dr. Lukasz Witek
Repair of critical-sized long bone defects using dipyridamole-augmented 3D-printed bioactive ceramic scaffolds. J Orthop Res. 2019;37:2499-507

Read more

Oral Reconstruction Foundation


Margarethenstrasse 38 

4053 Basel
Switzerland

Phone: +41 61 565 41 51
Email: info@orfoundation.org

OR Foundation – U.S. Section

2300 Riverchase Center
Birmingham, AL 35244
USA
Phone: +1 205 986 7989
Email: info.us@orfoundation.org

Newsletter

  • Facebook
  • Twitter
  • RSS

© Oral Reconstruction Foundation 2023 | Imprint | Disclaimer | Privacy | Sitemap | Professional websites Basel