OR Foundation
  • About
    • Oral Reconstruction Foundation
      • Purpose and Mission
      • Foundation Board
      • Scientific Working Group
      • Education Working Group
      • History
      • Career
      • News
  • Granting
    • Requirements
    • Application
  • Publications
    • Grant Publications
    • Consensus Publications
  • Awards
    • Research Award
      • Awards 2018/2019
      • Award 2016/2017
      • Award 2014/2015
      • Award 2012/2013
      • Award 2010/2011
      • Award 2008/2009
    • Poster Competition
      • Competition 2018
      • Competition 2016
      • Competition 2014
      • Competition 2012
  • Education
    • International Symposia
    • Global Symposia
    • National Symposia
    • Curriculum
    • Education Courses
    • Webinars
  • Contact
Select Page

Reproducibility of CBCT image analysis: a clinical study on intrapersonal and interpersonal errors in bone structure determination.


Schnutenhaus S, Graf M, Doering I, Luthardt RG, Rudolph H

Oral Radiol (2018) doi.org/10.1007/s11282-018-0340-1 [Epub ahead of print] (Grant CF41305)

Abstract

Objective:

For correct implant planning based on cone-beam computed tomography (CBCT), the bone contour must be accurately determined. Identification of the contour is difficult in bones with incomplete mineralization. In this clinical study, we investigated the intrapersonal and interpersonal reproducibilities of manual bone contour determination on CBCT images using a semi-automated computerized process.

Material and methods:

The bone surface level in the area of the socket in 20 patients who had undergone tooth extraction from the upper jaw at 10 ± 1 weeks previously was determined on CBCT images. Two investigators with different levels of experience determined the bone structure initially (T0) and repeated the procedure after 3 months (T1). The bone structure marked on CBCT images was converted into a surface data set. The resulting data sets were superimposed on one another. In the analyses, the shortest distances between the datasets were identified and measured. The average deviations were statistically evaluated.

Results:

The intrapersonal evaluation resulted in an average deviation of 0.18 mm across both investigators. The interpersonal analysis comparing the two investigators resulted in average deviations of 0.15 mm at T0 and 0.26 mm at T1. Significant differences were not found.

Conclusion:

The low intrapersonal deviation indicates that the procedure has satisfactory reproducibility. All deviations were within the range of the selected resolution of the CBCT device. Application of a semi-automated procedure to detect the bone border in areas with incomplete mineralization is a predictable process.

SOURCE

Latest Research Award Winners

Dr. Yifan Zhang
Quantitative Clinical Adjustment Analysis of Posterior Single Implant Crown in a Chairside Digital Workflow: A Randomized Controlled Trial. Clin Oral Impl Res. 2019;30:1059-1066

Read more

Dr. Hyun-Chang Lim
Tissue integration of zirconia and titanium implants with and without buccal dehiscence defects — A histologic and radiographic preclinical study. Clin Oral Impl Res. 2019;30:660-9

Read more

Dr. Lorenzo Tavelli
Acellular dermal matrix and coronally advanced flap or tunnel technique in the treatment of multiple adjacent gingival recessions. A 12-year follow-up from a randomized clinical trial. J Clin Periodontol. 2019;46:937-48

Read more

Dr. Lukasz Witek
Repair of critical-sized long bone defects using dipyridamole-augmented 3D-printed bioactive ceramic scaffolds. J Orthop Res. 2019;37:2499-507

Read more

Oral Reconstruction Foundation


Margarethenstrasse 38 

4053 Basel
Switzerland

Phone: +41 61 565 41 51
Email: info@orfoundation.org

OR Foundation – U.S. Section

2300 Riverchase Center
Birmingham, AL 35244
USA
Phone: +1 205 986 7989
Email: info.us@orfoundation.org

Newsletter

  • Facebook
  • Twitter
  • RSS

© Oral Reconstruction Foundation 2023 | Imprint | Disclaimer | Privacy | Sitemap | Professional websites Basel